{"id":15261,"date":"2024-10-19T17:23:09","date_gmt":"2024-10-19T15:23:09","guid":{"rendered":"https:\/\/www.enolia.fr\/?page_id=15261"},"modified":"2025-03-23T16:04:29","modified_gmt":"2025-03-23T15:04:29","slug":"cathodic-protection","status":"publish","type":"page","link":"https:\/\/www.enolia.fr\/?page_id=15261","title":{"rendered":"Cathodic Protection"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">1-Measure<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\">Measure plate for each type of enclosure<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:29% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"441\" height=\"333\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measurement-cathodic-protection-frame-3.png\" alt=\"cathodic protection frameboard\" class=\"wp-image-15274 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measurement-cathodic-protection-frame-3.png 441w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measurement-cathodic-protection-frame-3-300x227.png 300w\" sizes=\"auto, (max-width: 441px) 100vw, 441px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Each measure plate contains :<br>&#8211; Measurement on CE61010 plug (Diam 4mm) <br>Allowable current: 20A <br>Terminal block section: 2.5mm\u00b2 to 35mm\u00b2<br>&#8211; Insulating PVC support Removable shunt jumper<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 29%\"><div class=\"wp-block-media-text__content\">\n<p>This type of plate is used to perform measurement on cathodic protection system.<br>It is used to to have connections with measurement accessories and to measure the efficiency of the cathodic protection.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"316\" height=\"351\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measurement-cathodic-protection-frame-1.png\" alt=\"\" class=\"wp-image-15272 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measurement-cathodic-protection-frame-1.png 316w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measurement-cathodic-protection-frame-1-270x300.png 270w\" sizes=\"auto, (max-width: 316px) 100vw, 316px\" \/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Waterproof measuring tip<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:44% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"467\" height=\"258\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/waterproof-measuring-tip.png\" alt=\"\" class=\"wp-image-15284 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/waterproof-measuring-tip.png 467w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/waterproof-measuring-tip-300x166.png 300w\" sizes=\"auto, (max-width: 467px) 100vw, 467px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>This type of waterproof IP 67 measuring tip fits perfectly on cathodic protection cables.<br>For cable sections from 2.5mm\u00b2 to 16mm\u00b2, allowing potential measurement.<\/p>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Measuring box with jumper (number of channels upon request)<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"593\" height=\"211\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measuring-box-jumper-1.png\" alt=\"\" class=\"wp-image-15304 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measuring-box-jumper-1.png 593w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measuring-box-jumper-1-300x107.png 300w\" sizes=\"auto, (max-width: 593px) 100vw, 593px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Allowable current in a jumper: 20A max.     Section of connection cables: Flexible PC 10\u00b2<br>Cable sealing using low shrinkage epoxy resin.     Measurement on IEC61010 plugs (Diam 4mm).<br><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 26%\"><div class=\"wp-block-media-text__content\">\n<p>Link cut-off jumpers fit into keyholes. They are intended to make electrical connections. (rectifier\/anode, PP\/TM, insulating gasket, etc.) They are IP67 waterproof. Safety sockets (IEC 1010) are used to carry out quick and simple measurements by connecting standardized IEC 1010 leads. Each channel can be connected to different elements: pipe, metal indicator, permanent electrode, potential tap, etc.<\/p>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"440\" height=\"435\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measuring-box-jumper-2.png\" alt=\"\" class=\"wp-image-15305 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measuring-box-jumper-2.png 440w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/measuring-box-jumper-2-300x297.png 300w\" sizes=\"auto, (max-width: 440px) 100vw, 440px\" \/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Metallic indicator<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:17% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"137\" height=\"175\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/metallic-indicator-1.png\" alt=\"\" class=\"wp-image-15307 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Removable indicators allow measurements and recordings to be made on structures subject to cathodic protection.<\/p>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 23%\"><div class=\"wp-block-media-text__content\">\n<p>The surface indicator for manhole installation is intended to be installed permanently in manholes.<\/p>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"210\" height=\"128\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/metallic-indicator-2.png\" alt=\"\" class=\"wp-image-15308 size-full\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:22% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"172\" height=\"98\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/metallic-indicator-3.png\" alt=\"\" class=\"wp-image-15309 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<p>The indicator associated with a measuring well is intended to be placed near the pipe, and to be left permanently. It is associated with a DN 50 well to be able to slide an electrode into it.<\/p>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">2 &#8211; Anodes<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\">Ti\/MMO alloy anode in strings<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:25% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"331\" height=\"423\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anodes-Ti-MMO-string-1.jpg\" alt=\"\" class=\"wp-image-15312 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anodes-Ti-MMO-string-1.jpg 331w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anodes-Ti-MMO-string-1-235x300.jpg 235w\" sizes=\"auto, (max-width: 331px) 100vw, 331px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Titanium anodes electrocatalyzed by a mixed metal oxide (MMO) coating have the advantage of being able to withstand a high cathodic protection current.<\/p>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 22%\"><div class=\"wp-block-media-text__content\">\n<p>MMO titanium anodes consist of a titanium substrate coated with a mixture of precious metal oxides, typically including iridium, ruthenium and tantalum.\n The titanium substrate used in MMO anodes is highly resistant to corrosion, even in aggressive environments. This inherent strength helps protect the anode from degradation over time, contributing to its longevity.<\/p>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"291\" height=\"426\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-Ti-MMO-string-2.png\" alt=\"\" class=\"wp-image-15313 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-Ti-MMO-string-2.png 291w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-Ti-MMO-string-2-205x300.png 205w\" sizes=\"auto, (max-width: 291px) 100vw, 291px\" \/><\/figure><\/div>\n\n\n\n<p>The mixed metal oxide coating on the titanium substrate is designed to be stable and wear resistant. This coating retains its catalytic properties over extended periods, ensuring consistent performance throughout the life of the anode.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Anode mounted on a concrete base<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:38% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"410\" height=\"122\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-concrete-base-1.png\" alt=\"\" class=\"wp-image-15315 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-concrete-base-1.png 410w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-concrete-base-1-300x89.png 300w\" sizes=\"auto, (max-width: 410px) 100vw, 410px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><img loading=\"lazy\" decoding=\"async\" width=\"270\" height=\"89\" class=\"wp-image-15316\" style=\"width: 270px;\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-concrete-base-2.png\" alt=\"\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-concrete-base-2.png 925w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-concrete-base-2-300x99.png 300w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/anode-concrete-base-2-768x253.png 768w\" sizes=\"auto, (max-width: 270px) 100vw, 270px\" \/><\/p>\n<\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Magnesium alloy anode<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:15% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"255\" height=\"206\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/magnesium-alloy-anode-1.png\" alt=\"\" class=\"wp-image-15333 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-text-align-left\"><img loading=\"lazy\" decoding=\"async\" width=\"170\" height=\"75\" class=\"wp-image-15319\" style=\"width: 170px;\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/magnesium-alloy-anode-2.png\" alt=\"\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/magnesium-alloy-anode-2.png 666w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/magnesium-alloy-anode-2-300x132.png 300w\" sizes=\"auto, (max-width: 170px) 100vw, 170px\" \/><\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Fe-Silicium alloy anodes : Bare and Prebackfilled<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:37% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"380\" height=\"145\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/bare-Fe-Silicium-anode.png\" alt=\"\" class=\"wp-image-15320 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/bare-Fe-Silicium-anode.png 380w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/01\/bare-Fe-Silicium-anode-300x114.png 300w\" sizes=\"auto, (max-width: 380px) 100vw, 380px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"88\" class=\"wp-image-15336\" style=\"width: 250px;\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/pre-backfilled-Fe-Silicium-anode.png\" alt=\"\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/pre-backfilled-Fe-Silicium-anode.png 442w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/pre-backfilled-Fe-Silicium-anode-300x105.png 300w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/p>\n<\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Titane plated anode \/ Zinc anodes<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:15% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"155\" height=\"303\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/plated_titane_anode.png\" alt=\"\" class=\"wp-image-15339 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/plated_titane_anode.png 155w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/plated_titane_anode-153x300.png 153w\" sizes=\"auto, (max-width: 155px) 100vw, 155px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"112\" class=\"wp-image-15340\" style=\"width: 200px;\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/zinc_anode.png\" alt=\"\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/zinc_anode.png 342w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/zinc_anode-300x168.png 300w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><img loading=\"lazy\" decoding=\"async\" width=\"230\" height=\"89\" class=\"wp-image-15341\" style=\"width: 230px;\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/zinc_anode_2.png\" alt=\"\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/zinc_anode_2.png 443w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/zinc_anode_2-300x116.png 300w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/><\/p>\n<\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Backfill<\/h4>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:24% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"405\" height=\"240\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/backfill_1-1.png\" alt=\"\" class=\"wp-image-15346 size-full\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/backfill_1-1.png 405w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/backfill_1-1-300x178.png 300w\" sizes=\"auto, (max-width: 405px) 100vw, 405px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><img loading=\"lazy\" decoding=\"async\" width=\"180\" height=\"90\" class=\"wp-image-15344\" style=\"width: 180px;\" src=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/backfill_2.png\" alt=\"\" srcset=\"https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/backfill_2.png 715w, https:\/\/www.enolia.fr\/wp-content\/uploads\/2025\/03\/backfill_2-300x150.png 300w\" sizes=\"auto, (max-width: 180px) 100vw, 180px\" \/><\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>1-Measure Measure plate for each type of enclosure Each measure plate contains :&#8211; Measurement on CE61010 plug (Diam 4mm) Allowable current: 20A Terminal block section: 2.5mm\u00b2 to 35mm\u00b2&#8211; Insulating PVC support Removable shunt jumper This type of plate is used to perform measurement on cathodic protection system.It is used to to have connections with measurement&hellip; <br \/> <a class=\"button small blue\" href=\"https:\/\/www.enolia.fr\/?page_id=15261\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-15261","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.enolia.fr\/index.php?rest_route=\/wp\/v2\/pages\/15261","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.enolia.fr\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.enolia.fr\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.enolia.fr\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.enolia.fr\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15261"}],"version-history":[{"count":26,"href":"https:\/\/www.enolia.fr\/index.php?rest_route=\/wp\/v2\/pages\/15261\/revisions"}],"predecessor-version":[{"id":15347,"href":"https:\/\/www.enolia.fr\/index.php?rest_route=\/wp\/v2\/pages\/15261\/revisions\/15347"}],"wp:attachment":[{"href":"https:\/\/www.enolia.fr\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15261"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}